Normal Usage

  1. Turn probe on (Green light should come on)
  2. Log into QC
  3. Any form with a temperature sample control should cause the light on the probe to flash quickly for a few seconds. Leaving and reentering the form will cause QC to reattempt to contact the probe.

QC Form Setup

  1. Add sample control to your form
  2. Change Equipment Type to "Temperature"
  3. If a specific probe is required, enter the devices QC serial number into the Serial Number field.

Initial Setup for Windows Mobile

  1. Turn Probe on
  2. Goto Settings>>Connections>>Bluetooth
  3. Click “Add new device”
  4. Follow the steps in the wizard. When asked, the Passkey is 004321
  5. Click on the Intelliprobe in the Bluetooth devices list.
  6. Check the box “Serial Port” under Services to use
  7. Click “Save”
  8. Click on the “Com Ports” tab
  9. Click “New outgoing Port”
  10. Pick a com port (above 7 works better since several of them are used internally by most Handhelds)